Test Results

TECHNICAL DATA FOR RECYCLED PLASTIC

The following results were obtained using a standard 3-point test carried out on the 140mm x 38mm solid profile.
 

Parameter Description / Units 
Result
DENSITY      g/mm³  
  0.93
FLEXURAL STRENGTH Max Flexural stress sustained    by the specimen which caused it to rupture. Megapascals - ( Mpa)
21
MODULUS of
ELASTICITY
Mpa 
  889
IMPACT ENERGY  Impact required to rupture the specimen during the 3 point bending test. Millijoules - ( Mj)
346
MAXIMUM DEFLECTION The maximum downward   deflection prior to breaking. ( mm)
125
Method used conforms in broad principle to ISO 178:1993 (E)
WATER ABSORPTION IS0 62 : 1980 (E)
-0.67%

LABORATORY REPORT.

SALT TEST ON 140mm x 38mm SECTION.

The method used conforms to ASTM B117 (1000 hrs under a constant fog spray of 5% salt solution.)

RESULT: No discernible effect on sample.

SLIP RESISTANCE TESTS.

The method used conforms to BS 7976-2:2002, using a Four-S rubber slider pad.

Sample used
140mm x 38mm decking
Temperature and Condition
20° (Dry)
20° (Wet)
Pendulum Test Value Surface
72
54

Rapra Technology issued the following slip resistance guidance in January 1996:

Classification of Flooring
P. T. V. (Four S rubber)
Dangerous
24 and below
Marginal
25 - 34
Satisfactory
35 - 64
Excellent
65 and above **
Should you wish to print this information, there is a printable version on the downloads page.